1                            STATE OF OKLAHOMA

2   2nd Session of the 60th Legislature (2026)

3 HOUSE BILL 3913                         By: Dollens

4

5

6                            AS INTRODUCED

7   An Act relating to cities and towns; permitting

    municipalities to exercise authority under act;

8   permitting municipalities to authorize single-

    stairway apartment buildings that meet provided

9   criteria; providing for codification; and providing

    an effective date.

10

11

12 BE IT ENACTED BY THE PEOPLE OF THE STATE OF OKLAHOMA:

13  SECTION 1.      NEW LAW  A new section of law to be codified

14 in the Oklahoma Statutes as Section 43-117 of Title 11, unless there

15 is created a duplication in numbering, reads as follows:

16  A. A municipality may exercise the authority under this act

17 regardless of whether the municipality has adopted local amendments

18 to the International Building Code.

19  B. A municipality may authorize an apartment building to have a

20 single stairway only if the building:

21  1. Does not have more than six stories above grade plane and is

22 not a high-rise as defined by the International Building code, as

23 adopted by the Oklahoma Uniform Building Code Commission;

24  2. Does not have more than four dwelling units on any floor;

    Req. No. 14215                                            Page 1
1   3. Has automatic sprinkler locations in each interior exit

2 stairway, regardless of the type of stairway construction, that

3 comply with the requirements prescribed by National Fire Protection

4 Association Standard 13 for combustible stairways;

5   4. Has:

6   a. an exterior stairway, or

7   b. an interior exit stairway for which the doors:

8             (1) into the stairway from the interior of the

9                   building swing into the stairway regardless of

10                  the occupant load served, and

11            (2) from the interior exit stairway to the building

12                  exterior swing in the direction of exit travel;

13  5. Has interior exit stairway enclosures that:

14  a. have a fire resistance rating of not less than two (2)

15            hours, and

16  b. do not contain an elevator opening;

17  6. Has on each floor a corridor from each dwelling unit entry

18 or exit door to an interior exit stairway, including any related

19 exit passageway, that has a fire resistance rating of at least one

20 (1) hour;

21  7. Does not have more than twenty (20) feet between the entry

22 or exit door of a dwelling unit and an exit stairway;

23  8. Does not have more than one hundred twenty-five (125) feet

24 of exit access travel distance;

    Req. No. 14215                                              Page 2
1   9. Has an exit serving the portion of the building that

2 contains two or more dwelling units that does not discharge through

3 a portion of the building with a different occupancy category,

4 including an accessory parking garage;

5   10. Has an exit that terminates in an egress court for which

6 the court depth does not exceed the court width, unless it is

7 possible to exit the egress court to the public way in either

8 direction;

9   11. Does not have an opening within ten (10) feet of an

10 unprotected opening into an exit stairway other than a required exit

11 door that has a fire resistance rating of at least one (1) hour;

12  12. Has emergency escape and rescue openings that comply with

13 Section 1031 of the International Building Code, as adopted by the

14 Oklahoma Uniform Building Code Commission, on each floor served by a

15 single exit;

16  13. Does not have an electrical receptacle in an interior exit

17 stairway; and

18  14. Has an automatic smoke and fire detection system that

19 activates an occupant notification system that complies with Section

20 907.5 of the International Building Code as adopted under Section

21 214.216 installed in each:

22  a. common space outside of a dwelling unit,

23  b. laundry room, mechanical equipment room, and storage

24                room,

    Req. No. 14215                                                Page 3
1   c. interior corridor serving a dwelling unit, and

2   d. main floor landing or interior or exterior exit

3   stairway.

4   SECTION 2. This act shall become effective November 1, 2026.